beautypg.com

Menu selection and settings, 2 cw nor, 4 datanar2 – Vertex Standard FT-1000MP User Manual

Page 104: 8 sub-fil, 9 t-fil, 0 rtty-shf, 1 rtty-pol, 2 rtty-ton, 3 rty-fdsp, 4 pac-fdsp

background image

Page 102

O

PERATING

M

ANUAL

5-1 8.2-2.0

2nd IF 2.0 kHz Filter - Enables/disables the op-

tional 2.0 kHz IF filter (Yaesu P/N YF-114SN).

5-2 CW nor

CW Normal Filters - Selects the CW filters used

when the front-panel [NOR] switch is selected (while
in the CW mode).

8.2 - Sets the 2nd IF to the optional 2.0 kHz filter,
and the 3rd IF to the 2.4 kHz filter.

455 - Sets the 2nd IF to the 2.4 kHz filter, and the
3rd IF to the optional 2.0 kHz filter.

8.2-455 - Sets the 2nd IF and 3rd IF filters to 2.0
kHz filter options.

Note: If you have not installed the optional 2.0 kHz

filters (or if you disable the optional 2.0 kHz filters by
menu selection 5-1 and/or 5-5), the received signal will
pass through the standard 2.4 kHz filter.

5-3 8.2-250

2nd IF 250 Hz Filter - Enables/disables the optional

250 Hz IF filter (Yaesu P/N YF-114CN).

5-4 dAtAnAr2

DATA Narrow 2 Filters - Selects the filters used

when the front-panel [NAR2] switch is selected (while
in the DATA mode).

8.2 - Sets the 2nd IF to the optional 250 Hz filter,
and the 3rd IF to the optional 500 Hz filter.

455 - Sets the 2nd IF to the 500 Hz filter, and the
3rd IF to the optional 250 Hz filter.

8.2-455 - Set the 2nd IF and 3rd IF filters to the 250
Hz filter options.

Note (1): If you have not installed the optional 2nd

IF 500 Hz filter (or if you disable the filter by menu se-
lection 5-3
), the received signal will pass through the
supplied 500 Hz filter.

Note (2): If you have not installed the optional 3rd

IF 500 Hz filter (or if you disable the filter by menu se-
lection 5-6
), the received signal will pass through the
supplied 2.4 kHz filter.

Note (3): If you have not installed the optional 3rd

IF 250 Hz filter (or if you disable the filter by menu se-
lection 5-7
), the received signal will pass through the
supplied 2.4 kHz (or optional 500 Hz) filter.

5-5 455-2.0

3rd IF 2.0 kHz Filter - Enables/disables the op-

tional 2.0 kHz IF filter (Yaesu P/N YF-110SN).

Menu Selection and Settings

5-6 455-500

3rd IF 500 Hz Filter - Enables/disables the optional

500 Hz IF filter (Collins YF-115C).

5-7 455-250

3rd IF 250 Hz Filter - Enables/disables the optional

250 Hz IF filter (Yaesu P/N YF-110CN).

5-8 Sub-FiL

SUB VFO Filter - Enables/disables optional SUB

VFO-B 2nd IF 500-Hz CW filter (Collins YF-115C).

5-9 t-FiL

TX EDSP Filter - Selects either a 6.0-kHz or 2.4-

kHz digital bandpass filter for early-stage transmit au-
dio tailoring.

6-0 rttY-SHF

RTTY Frequency Shift - Selects 170, 425, or 850

Hz standard frequency shift for FSK RTTY operation.

Important Note! - If changing RTTY shift to other

than 170 Hz, be sure to re-calibrate the tuning meter
as outlined on page 85. The calibration routine is simple,
and ensures your center tuning indication matches the
tone pair.

6-1 rttY-PoL

RTTY Polarity - Selects normal or reverse Mark/

Space polarity for RTTY operation. Normal operation
utilizes a 2125-Hz mark frequency, while reverse uses
2295 Hz. See the table on page 17 for a list of stan-
dard tone pairs.

6-2 rttY-ton

RTTY Tone - Selects high or low mark tone for

RTTY operation. See the table on page 17 for a com-
parison of high/low tone pairs.

6-3 rtY-FdSP

RTTY Frequency Display - Selects the type of dis-

play offset that appears during RTTY operation.

Offset - Displays the RTTY BFO offset.

Carrier - Displays the actual carrier frequency.

6-4 PAc-FdSP

Packet Frequency Display Offset - You can off-

set the frequency readout to display the center fre-
quency between the two transmitted carriers (tone
pairs). Rotate the MAIN VFO-A knob to adjust the dis-
play offset, or else set to 0.00 to display the actual car-
rier frequency. See menu selection 6-5 below for tone
pair selection.