8.4.1. LED setting by communication

Desired

LED information can be displayed by communication.


Set the standard monitor display selection parameter to “communication LED setting (=).”
When in the standard monitor mode status, LED information is displayed according to the setting of
Communication Number FA65. (Is set to Communication Number FA65 = 1 and initial data “dAtA”
in

shipment setting)

In case of an alarm while setting communication LEDs, the alarm display will alternately display
specified LED data and alarm message.
For example, if an over-current alarm (alarm display “”) occurs while “.” is displayed by this
function, “” and “.” will be displayed alternately.

Commu-

nication

Number.

Parameter Name

Range

Shipment

setting

FA65

Select display by communication

0: Numeric data (FA66, FA67, FA68)
1: ASCII data 1 (FA70, FA71, FA72, FA73,

FA74)

2: ASCII data 2 (FA75, FA76, FA77, FA78,

FA79)

1

FA66

Numeric display data
(Enabled if FA65=0)

0-9999

0

FA67

Decimal point position
(Enabled if FA65=0)

0: No decimal point (xxxx)
1: First digit below decimal point (xxx.x)
2: Second digit below decimal point (xx.xx)

0

FA68

LED data 0 for unit
(Enabled if FA65=0)

0:Hz off, % off, 1:Hz on, % off
2:Hz off, % on, 3:Hz on, % on

0

FA70

ASCII display data 1, first digit from
left
(Enabled if FA65=1)

0 – 127 (0 – 7FH)
(See ASCII LED display code chart)

64H (’d’)

FA71

ASCII display data 1, second digit
from left
(Enabled if FA65=0)

0 – 256 (0 – FFH)
(See ASCII LED display code chart)

41H (’A’)

FA72

ASCII display data 1, third digit from
left
(Enabled if FA65=1)

0 – 256 (0 – FFH)
(See ASCII LED display code chart)

74H (’t’)

FA73

ASCII display data 1, fourth digit from
left
(Enabled if FA65=1)

0 – 127 (0 – 7FH)
(See ASCII LED display code chart)

41H (’A’)

FA74

LED data 1 for unit
(Enabled if FA65=1)

0:Hz off, % off, 1:Hz on, % off
2:Hz off, % on, 3:Hz on, % on

0

FA75

ASCII display data 2, first digit from
left
(Enabled if FA65=2)

0 – 127 (0 – 7FH)
(See ASCII LED display code chart)

30H (’0’)

FA76

ASCII display data 2, second digit
from left
(Enabled if FA65=2)

0 – 256 (0 – FFH)
(See ASCII LED display code chart)

30H (’0’)

FA77

ASCII display data 2, third digit from
left
(Enabled if FA65=2)

0 – 256 (0 – FFH)
(See ASCII LED display code chart))

30H (’0’)

FA78

ASCII display data 2, fourth digit from
left
(Enabled if FA65=2)

0 – 127 (0 – 7FH)
(See ASCII LED display code chart)

30H (’0’)

FA79

LED data 2 for unit
(Enabled if FA65=2)

0:Hz off, % off, 1:Hz on, % off
2:Hz off, % on, 3:Hz on, % on

0