■ Relating communication parameters

Following parameters should be set or changed if necessary.

• Communication baud rate ()... Shipment setting = : 9600bps
Baud rate of all inverters in the network (master and slave) should be same network.

• Parity () ... Shipment setting = : Even parity
Parity of all inverters in the network (master and slave) should be same network.

• Communication error trip time() ... Shipment setting = 
Operation is continued by the last received command value in the case of a communication break-
down. To stop the operation of inverter, provide a communication time-out interval (ex. =)
to the slave inverters. The master inverter does not trip even though the communication breakdown
happens. To trip the master inverter, provide an interlock mechanism by installing a FL fault relay
point or the like from the slave side.

• Frequency point selection ()

Adjusted to the system.

See chapter “6.1 Speed proportional control” for details.

■ Setting example of parameters

Parameters relating to the master side (example)



Master (transmission of output frequency

(%) (100% at FH))


Selection of communication protocol

(Toshiba inverter protocol)


Communication baud rate

(ex. 19200bps)



Parity (even parity)



Example: Panel



Example: Built-in potentiometer



Communication waiting time

(ex. 30msec)

Parameters relating to the slave side (example)



Slave (0Hz command issued in case the master inverter

fails)



Selection of communication protocol

(Toshiba inverter protocol)


Communication time-out (ex. 1 second)



Communication baud rate (same to the master side)



Parity (same to the master side)



Terminal block (ex. Driven by F, ST)

( Run and stop of operation is controlled with the frequency

reference value by setting the “run frequency”.)

< For speed control >


Serial communication



? Adjusted to the system Point 1 setting (%)



? Ditto Point 2 frequency (Hz)



? Ditto Point 2 setting (%)



? Ditto Point 2 frequency (Hz)