Dc user accessible fuse replacement, Dc user accessible fuse replacement -7, Figure 7.2: fuse carrier -7 – TANDBERG High Definition Professional Recevier/Decoder TT1280 User Manual
Page 81: 2 dc user accessible fuse replacement
Preventive Maintenance and Fault-finding
Reference Guide: TT128x High Definition Professional Receiver/Decoder
Page 7-7
ST.RE.E10141.5
Figure 7.2: Fuse Carrier
If the replacement fuse also blows, do not continue. Disconnect the
equipment and contact TANDBERG Customer Services (see Preliminary
Pages) for advice.
7.5.2
DC User Accessible Fuse Replacement
WARNING…
BEFORE REPLACING THE REAR PANEL FUSE, ISOLATE THE UNIT FROM THE SUPPLY.
FAILURE TO ISOLATE THE EQUIPMENT PROPERLY MAY CAUSE A SAFETY HAZARD.
NOTE…
Refer to Annex B, Technical Specification for information about the DC fuse.
To replace the DC power fuse:
1. Ensure that DC power is turned off or the power cable is disconnected
from the power inlet.
2. Unscrew the fuse carrier and remove the old fuse (see Figure 7.3).
CAUTION...
When replacing the power input fuse, always ensure that a fuse of the correct type and rating, is fitted.
Failure to do so results in inadequate protection.
3. Insert the new fuse in the carrier.
4. Insert the fuse carrier back in the DC power inlet.
Figure 7.3: Position of Fuse Carrier for -48 Vdc Input
AC Power Inlet
Fuse Carrier
To access the fuse, ease out the notch
with a small flat-blade screwdriver.
Fuse Carrier