beautypg.com

Alarm connector and relay, Alarm connector and relay -15, Outputs -15 – TANDBERG High Definition Professional Recevier/Decoder TT1280 User Manual

Page 35: Table 2.9: alarm connector -15, Connector -15, 8 alarm connector and relay

background image

Installing the Equipment

Reference Guide: TT128x High Definition Professional Receiver/Decoder

Page 2-15

ST.RE.E10141.5

2.8.8

Alarm Connector and Relay

The alarm relay connector has a summary and four

general purpose relays. The summary relay is

activated whenever the unit detects an alarm, or the

power is switched off.

Table 2.9: Alarm Connector

Item Specification

Connector type

9-way, D-type, Female for the summary alarm relay

Connector designation

ALARM RELAY

Pin-outs Pin 1 Relay 2, Normally open

Pin 2 Relay 3, Normally open
Pin 3 Relay 4, Normally closed
Pin 4 Relay 1, common pin
Pin 5 Relay 5, Normally closed
Pin 6 Relays 2 and 3, common pin
Pin 7 Relays 4 and 5, common pin
Pin 8 Relay 1, Normally Closed (Open on Alarm)
Pin 9 Relay 1, Normally Open (Closed on Alarm)

2.8.9

RS-232 Low-speed Asynchronous and RS-422

High-speed Synchronous Data Outputs

A 9-way, D-type female connector provides a shared

simultaneous asynchronous low-speed data and

synchronous high-speed data serial communications

interface. The status of the data output on this

connector is given in the Data menus (Menus 3.4

and 3.5).

Table 2.10: RS-232 Low-speed/RS-422 High-speed Data Connector

Item Specification

Connector type

9-way, D-type, Female

Connector designation

RS232/RS422 Data Out

Standards

RS-232 DATA/RS-422 DATA

Configuration DCE
Pin-outs



Pin 1

 CLK (RS-422)

Pin 2

 Receive Data Output (RxD) (RS-232)

Pin 3

 Not Used

Pin 4

 Not Used

Pin 5

 Ground (RS-232)

Pin 6

 CLK (inverted) (RS-422)

Pin 7

 Not used

Pin 8

 DATA (RS-422)

Pin 9

 DATA (inverted) (RS-422)

ALARM RELAY

RS232/RS422 Data Out

This manual is related to the following products: