Dc supply input (-48 v version), Cable types, B.7.2 – TANDBERG High Definition Professional Recevier/Decoder TT1280 User Manual
Page 114: B.8 cable types, B.7.2 dc supply input (-48 v version)
Technical Specification
Page B-22
Reference Guide: TT128x High Definition Professional Receiver/Decoder
ST.RE.E10141.5
B.7.2
DC Supply Input (-48 V Version)
NOTES...
1. Only models TT1280/CIBAS/48V, TT1280/DIRBAS/48V, TT1282/CIBAS/48V and
TT1282/DIRBAS/48V use a DC power supply.
2. Ensure correct polarity is maintained.
3. The unit must have a protective earth.
Table B.33: DC Power Supply Specification
Item Specification
Rated voltage
For connection to –48 Vdc supplies only.
(PSU input tolerance –40 to –60 Vdc). Correct polarity must always be observed.
Rated current
2 A
Input connector
Terminal block
Fuse
Fuse in –48 Vdc connector at rear of unit.
Fuse type
Bussmann S505
Littelfuse 215
5x20mm time delay (T) 1500A breaking capacity (HBC)
IEC/EN 60127-2 Sheet 5
Fuse current rating
5 A 250 V T HBC
Power consumption
45 W typical (NO options fitted)
180 W maximum
B.8 Cable
Types
The signal cable types (or similar) in Table B.34 are those recommended
by TANDBERG Television in order to maintain product EMC compliance.
Table B.34: Suitable Signal Cable Types
Signal Type
Connector
Cable
RS-232/RS-422 Data Out
9-way D-type Male
Belden 8162 CM 2PR24 shielded E108998 (typical)
Alarm Relay
9-way D-type Male
Belden 8162 CM 2PR24 shielded E108998 (typical)
ASI/HDSDI Out 1 and 2
BNC
Canford Audio BBC 1/3 PSF (type 2 video cable)
ASI/SMPTE 310 In
BNC
Canford Audio BBC 1/3 PSF (type 2 video cable)
Frame Sync
BNC
Canford Audio BBC 1/3 PSF (type 2 video cable)
Ethernet (100BaseT)
RJ-45
CAT 5E Data Cable S-FTP
Audio 1 and 2
9-way D-type Male to XLR
Canford Audio Cable DST 110 Ω
Video Out
15-way D-type Male
Five-way screened Haurtian computer cable EL164535 ‘D’