High-speed data over ethernet, Snmp remote control connector, Alarm connectors – TANDBERG High Definition Professional Recevier/Decoder TT1280 User Manual
Page 111: B.5.4, Snmp remote control connector............. b-19, B.5.5, B.5.4 snmp remote control connector, B.5.5 alarm connectors

Technical Specification
Reference Guide: TT128x High Definition Professional Receiver/Decoder
Page B-19
ST.RE.E10141.5
Table B.26: RS-422 Synchronous (High-speed) Data Connector
Item Specification
Safety status
SELV
Connector type
9-Way D-type
Connector designation
RS232/RS422 DATA OUT
Data-rates (bit/s)
Integer multiples of 56 kbit/s and 64 kbit/s
Standards
EIA RS-422/ ITU-T V.11
Line length
< 1200 metres
High-Speed Data over Ethernet
This connector is located at the back of the unit using the RJ-45 Ethernet
port and is enabled through the licence key (TT1280/SWO/HSETHER).
Table B.27: High-speed Data Over Ethernet Connector
Item Specification
Safety status
SELV
Connector Type
RJ-45 (100BaseT)
Connector designation
Data-rates (bit/s)
5 Mbit/s
Standards
ETSI EN 301 192 v.1.2.1 (1999-06), section 4
De-encapsulation type
Data Piping (Proprietary)
B.5.4
SNMP Remote Control Connector
Table B.28: SNMP Control Connector
Item Specification
Safety status
SELV
Connector type
RJ-45 (100BaseT)
Connector designation
10/100BaseT
Standard
TANDBERG SNMP Control MIB
B.5.5 Alarm
Connectors
Table B.29: Relay Alarm Output Specification
Item
Specification
Safety status
SELV
Connector type
9-way D-type female
Connector designation:
ALARM
Contact Configuration
SPDT (Change-over)
All volt-free contacts, fully isolated.
Contact Rating
1 A at 24 Vdc
1 A at 50 Vac
Maximum Switching Current
1 A