Toshiba B-570 User Manual
Page 75
6-44
EM18-33010A
6. DIAG. TEST OPERATION
NOTES:
1. When there is no change to the print condition, select one of the test print options to issue the test
print.
2. Holding the [FEED] key or [RESTART] key down for more than 0.5 seconds enables a fast forward.
3. A selected print condition is activated when the [PAUSE] key is pressed.
4. When the feed gap sensor is selected, the gap between labels becomes 3mm long.
5. Non-transmissive (NON TRANS.) ribbon cannot be used so the ribbon type must be set to
transmissive (TRANS.) ribbon or no ribbon.
6. A label size greater than the image buffer length cannot be designated. The image buffer length
differs according to memory size. If designated, the printer prints in the image buffer, or the printer
stops because of an error.
7. Pressing the [FEED] key changes the label length -1 mm, pressing the [RESTART] key changes
+1 mm.
8. When an error occurs during a test print, the error message is displayed and printing is stopped.
The error is cleared by pressing the [PAUSE] key and the display shows “<3> TEST PRINT”.
Printing is not automatically resumed after the error is cleared.
(Revision Date Feb. 07, ’97)
6.4 TEST PRINT MODE
< 3
T E S T
P R I N T
>
< 3
T E S T
P R I N T
>
P R
N T
C O N D I T I O N
I
From B of the preceding page.
Press the [PAUSE] key.
From A of the
preceding page.
SLANT LINE (1 DOT)
SLANT LINE (3 DOT)
CHARACTERS
BAR CODE
NON-PRINTING
FACTORY TEST PATTERN
AUTO PRINT (TRANS.)
Process test print/
Transmissive sensor
AUTO PRINT (REFLECT.)
Process test print/
Reflective sensor
Select the test print from
those at the right by
pressing the [FEED] key
or [RESTART] key.
A designated number of
test prints are issued when
pressing the [PAUSE] key.
(See NOTE 8.)
Press the [FEED] key
and [RESTART] key at
the same time.
Press the [PAUSE] key.