6. DIAG. TEST OPERATION

[FEED] key:

Pressing the [FEED] key one time
is a -0.5 mm change, up to -50.0
mm. (See NOTE 2.)

[RESTART] key: Pressing the [RESTART] key one

time is a +0.5 mm change, up to
+50.0 mm.
(See NOTE 2.)

6.3 PARAMETER SETTING MODE

6.3.1

Feed Length Fine Adjustment

NOTES: 1. Holding the [FEED] key or [RESTART] key down for more than 0.5 seconds enables

a fast forward.

2. Max. fine adjustment

±

50.0 mm = Key fine adjustment value (

±

50.0 mm) + PC fine

adjust ment value (

±

50.0 mm)

When the value reaches the maximum, the value remains unchanged even if the

subsequent fine adjustment is performed.

3. A change feed value is stored in memory by pressing the [PAUSE] key.

< 1

D I A G N O S T I C

V 1 . 0 A

>

< 2

P A R A M E T E R

S E T

>

Power off

F E

D

A D J U S T

+ 0 . 0 m m

E

Turn on the power while
holding down the [FEED]
key and [PAUSE] key.

Press the [FEED] key.

Press the [PAUSE] key.

Press the [FEED] or
[RESTART] key to adjust
the feed length.
(See NOTE 1.)

Press the [FEED] key
and [RESTART] key
at the same time.

Press the [PAUSE] key.

Continued on Section 6.3.2
Cut/strip position fine adjustment.