6. DIAG. TEST OPERATION

6.3.10 Ribbon Motor Drive Voltage Fine Adjustment

NOTES: 1. Holding the [FEED] key or [RESTART] key down for more than 0.5 seconds enables

a fast forward.

2. Max. fine adjustment -15 steps = Key fine adjustment value (-15 steps) + PC fine

adjustment value (-15 steps)

When the value reaches the maximum, the value remains unchanged even if the

subsequent fine adjustment is performed.

3. A changed motor voltage value is stored in memory by pressing the [PAUSE] key.
4. One step corresponds to 5% of the standard voltage and up to 75% of the voltage

can be decreased.

(Revision Date Jun. 28, ’96)

6.3 PARAMETER SETTING MODE

(Ribbon feed motor voltage fine adjustment)

[FEED] key:

Pressing the [FEED] key one time is a
-1 step change, up to -15 steps.
(See NOTE 2.)

[RESTART]key: Pressing the [RESTART] key one time

is a -1 step change, up to -15 steps.
(See NOTE 2.)

[FEED] key:

Pressing the [FEED] key one time is a
-1 step change, up to -15 steps.
(See NOTE 2.)

[RESTART]key: Pressing the [RESTART] key one time

is a -1 step change, up to -15 steps.
(See NOTE 2.)

(Ribbon rewind motor voltage fine adjustment)

Power off

Turn on the power while
holding down the [FEED]
key and [PAUSE] key.

Press the [FEED] key.

Press the [PAUSE] key eleven times.

Press the [FEED] or
[RESTART] key to fine
adjust the feed motor
voltage. (See NOTE 1.)

Press the [PAUSE] key.
(See NOTE 3.)

Press the [FEED] or
[RESTART] key to fine
adjust the rewind motor
voltage. (See NOTE 1.)

Press the [FEED] key
and [RESTART] key
at the same time.

< 1

D I A G N O S T I C

V 1 . O A

>

< 2

P A R A M E T E R

S E T

>

<

>

R I

B O N

A D J

F W D

+ 0

B

<

>

R I

B O N

A D J

B A K

+ 0

B