beautypg.com

Toshiba B-570 User Manual

Page 67

background image

6-36

EM18-33010A

6. DIAG. TEST OPERATION

(Revision Date: Jan. 14 ‘99)

6.3 PARAMETER SETTING MODE

NOTE:

The following operation cannot be performed unless the sensor type is changed by the issue

command or feed command.

(1) Using the sensor adjustment in Diag. mode, measure the sensor voltage at the following four points.

Label:

Print area Backing paper

Tag paper: Print area Black mark
Example:

(2) Using the following formula, calculate the threshold from the measured voltage:

When using labels (transmissive sensor):

Threshold = (Max. voltage at the backing paper) - (Voltage at the print area) - 0.7V

e.g.)

2.0V = 4.2V - 1.5V - 0.7V

When using perforated labels (transmissive sensor):

Threshold =

(Max. voltage at the backing paper) Min. voltage at the backing paper

Max. voltage at the backing paper

e.g.)

2.2V = 4.4V - (2.8V/2) - (1.6V/2)

When using labels with black marks (reflective sensor):

Threshold = (Min. voltage at the print area) - (Min. voltage at the black mark)

e.g.)

0.4V = (1.5V - 0.7V)/2

[ R E F L E C T I V E ] 2 . 8 V

[ T R A N S M I S S I V E ] 4 . 1 V

2

2

2

-

-

A

A

B

C

D

Backing Parper

Label

Perforation

B

(2.8 V)

A

(4.4 V)

D

(0.7 V)

C

(1.5 V)

Backing Paper

Label

Black Mark

Label gap