6. DIAG. TEST OPERATION

NOTES: 1. Holding the [FEED] key or [RESTART] key down for more than 0.5 seconds enables

a fast forward.

2. Max. fine adjustment

±

99.5 mm = X axis value

When the value reaches the maximum, the value remains unchanged even if the

subsequent fine adjustment is performed.

3. A changed X axis is stored in memory by pressing the [PAUSE] key.

[FEED] key:

Pressing the [FEED] key one
time is a -0.5 mm change, up to
-99.5 mm. (See NOTE 2.)

[RESTART] key: Pressing the [RESTART] key

one time is a +0.5 mm change,
up to +99.5 mm. (See NOTE 2.)

6.3 PARAMETER SETTING MODE

6.3.4

X Axis Fine Adjustment

Power off

< 1

D I A G N O S T I C

V 1 . 0 A

>

< 2

P A R A M E T E R

S E T

>

X

D J U S T

+ 0 . 0 m m

A

Turn on the power while
holding down the [FEED]
key and [PAUSE] key.

Press the [FEED] key.

Press the [PAUSE] key four times.

Press the [FEED] or
[RESTART] key to fine
adjust the print position
along the X axis.
(See NOTE 1.)

Press the [FEED] key
and [RESTART] key
at the same time.

Press the [PAUSE] key.

Continued on Section 6.3.5