beautypg.com

Toshiba B-570 User Manual

Page 35

background image

6-4

EM18-33010A

6. DIAG. TEST OPERATION

#

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

NOTES:

1. Item from (2) through (10) are initialized to “0” after RAM clear.
2. If the distance is 5.5 m or less, it is rounded down and no data is added to the memory at power

off.

3. If the count is 31 counts or less, it is rounded down and no data is added to the memory at

power off.

4. If the driving time is 27 sec. or less, it is rounded down and no data is added to the memory

at power off.

5. When a sent command results in an error, the same number as the data capacity of the

command is counted by byte.

Fig. 6-1

(Revision Date: Dec. 10 ‘99)

6.2 SELF TEST MODE

Sample Print
[Print Condition]

Preset count

: 1

Print speed

: 127 mm/sec.

Sensor

: No sensor

Printing method : Thermal transfer

Supply length

: 50 mm

Issuing mode

: Batch printing

(without rewinder)

1) Maintenance Counter

Item

Total media distance
covered
Media distance

Print distance

Cut count

Head up and down
count

Ribbon motor driving
time

Solenoid driving time

RS-232C hardware
error count

System error count

Momentary power
failure count

Count Condition

Counted when the feed motor drives to feed, print and
issue the media. (Counted also during ribbon save
operation and back feed.) [See NOTE 2].

Counted while printing. (Feeding and issuing media,
and ribbon saving operation are not counted.)
[See NOTE 2.]

Counts every cut. [See NOTE 3.]

Counts every up and down of the print head using the
solenoid for ribbon save operation.
(Up + Down = 1 count) [See NOTE 3.]

Counts when the ribbon motor drives to feed, print
and issue the media. (The driving time is not counted
during ribbon saving operation, but is during back
feed.) [See NOTE 4.]

Counted during ribbon saving operation.
[See NOTE 4.]

Counted when a parity, overrun or framing error
occurs. [See NOTE 5.]

Counted when a zero-dividing error occurs or
undefined command is retrieved.

Counted when a momentary power failure occurs.

Range

0.0 ~ 3200.0 km

0.0 ~ 200.0 km

0.0 ~ 200.0 km

0 ~ 1000000 times

0 ~ 2000000 times

0 ~ 2000 hours

0 ~ 1000 hours

0 ~ 255 times

0 ~ 15 times

0 ~ 15 times

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

(11)

(12)

(13)

(25)

(26)

(27)

(28)

(29)

(30)

(31)

(32)

(33)

TL FEED

1882.3km

FEED

20.5km

PRINT

15.0km

CUT

148150

HEAD U/D

170

RIBBON

32h

SOLENOID

0h

232C ERR

1

SYSERR

0

PW FAIL

0

FONT

[PC-850] [0]

CODE

[ESC LF NUL]

RIBN

[TRANS.]

[PC]
FEED

-10.0mm

CUT

-5.0mm

BACK

+3.0mm

TONE(T)

+3step

TONE(D)

+5step

[KEY]
FEED

+5.0mm

CUT

-1.5mm

BACK

+0.5mm

TONE(T)

+0step

TONE(D)

+1step

X ADJ.

+35.0mm

RIBN ADJ. [PC] + 0 +0 [KEY] + 0 +0
STATUS [OFF]
THRESHOLD R 1.0V
THRESHOLD T 1.4V
KANJI [TYPE1]
EURO CODE B0H
STACKER [OFF]
DTR/RTS [DTR]
INPUT PRIME [ON]

(14)

(15)

(16)

(17)

(18)

(19)

(20)

(21)

(22)

(23)

(24)