Installing the Equipment

Instruction Manual: TT1260 Standard Definition Professional Receiver/Decoder

Page 2-13

ST.TM.E10100.1

Remote Control

Connect to a PC and use the System Menu

#6.1.2 to switch between the RS-232 and

RS-485 input standards.

The specification for this connector is given in

Section B.5.4, Remote Connector. The Remote

Control Protocol is published in manual

ST.TS.E10100, and in the TANDBERG Television

RS-232 remote control protocol document.

RS232/RS485 REMOTE

Table 2.10: Remote Control Connector

Item

Specification

Connector type

9-way, D-type, Male

Connector designation

RS232/RS485REMOTE

RS-232

RS-485

Pin-outs

Pin
1
2
3
4
5
6
7
8
9

Data Carrier Detected (DCD)
Receive Data (RxD)
Transmit Data (TxD)
Data Terminal Ready (DTR)
Ground
Data Set Ready (DSR)
Request to Send (RTS)
Clear to Send (CTS)
Not connected

Direction
Input
Input
output
output

input
output
input

Pin
1
2
3
4
5
6
7
8
9

Not connected
Not connected
Not connected
Rx
Ground
Not Tx
Tx
Not Rx
Not connected

Alarm Connector and Relay

The master alarm relay connector has a summary

relay. The relay is activated whenever the unit is

in alarm status, or the power is switched off.

ALARM

Table 2.11: Alarm Connector

Item

Specification

Connector type

9-way, D-type, Female

Connector designation

ALARM

Pin-outs

Pin 1

¾ N/C

Pin 2

¾ N/C

Pin 3

¾ N/C

Pin 4

¾ Common

Pin 5

¾ N/C

Pin 6

¾ N/C

Pin 7

¾ N/C

Pin 8

¾ Normally Closed (Open on Alarm)

Pin 9

¾ Normally Open (Closed on Alarm)