Environmental, Conditions, Physical – TANDBERG TT1260 User Manual
Page 111: Power supply, B.7 environmental, B.8 power supply, B.7.1 conditions, B.7.2 physical
Technical Specification
Instruction Manual: TT1260 Standard Definition Professional Receiver/Decoder
Page B-19
ST.TM.E10100.1
B.7
Environmental
B.7.1
Conditions
Table B.28: Environmental Conditions
Operational
Temperature
0
°C to +45°C (+32°F to +113°F) ambient air temperature with free airflow
Humidity
0% to 95% (non-condensing)
Cooling requirements
Convection cooling/free airflow
Handling/movement
Fixed (non-mobile) use only
Storage/Transportation
Temperature
-20
°C to +70°C (-4°F to +158°F)
Humidity
0% to 95% (non-condensing)
B.7.2
Physical
Table B.29: Physical Parameters
Parameter
Performance
Height
44.3 mm
Width
442 mm (without rack fixing brackets)
482 mm (with rack fixing brackets)
Depth
350 mm (including connectors)
Rack mounting standard
1U x 19 inches (1U
º 44.45 mm)
Weight
Weight 4.5 - 5.0 kg depending on configuration
B.8
Power Supply
This equipment is fitted with an auto-ranging power supply. It is suitable
for supply voltages of 100-120 Vac -10% +6% or 200-250 Vac -10% +6%
at 50/60 ± 3 Hz nominal.
Table B.30: Power Supply Specifications
Item
Specification
Power distribution system
Type TN, and IT for Norway, ONLY (Defined in EN 60950).
TN: Power distribution system having one point directly earthed, the exposed
conductive parts of the installation being connected to that point by protective earth
conductors. This equipment must NOT be used with other single-phase three-wire
and PE, TT or IT Type Power distribution systems.
Connection to supply
Pluggable Equipment Type A (Defined in EN 60950): Equipment that is intended for
connection to the building power supply wiring via a non-industrial plug and
socket-outlet or a non-industrial appliance Coupler or both. Correct mains polarity
must always be observed. Do not use reversible plugs with this equipment.
Class of equipment
Class I and Pluggable Equipment Type A (Defined in EN 60950): electric shock
protection by basic insulation and protective earth.
Rated voltage
100 – 120 Vac
200 – 250 Vac