Data outputs, Rs-232 asynchronous (low-speed) data, Rs-422 synchronous (high-speed) data – TANDBERG TT1260 User Manual
Page 109: Remote control connector, B.6.3 data outputs, B.6.4 remote control connector
Technical Specification
Instruction Manual: TT1260 Standard Definition Professional Receiver/Decoder
Page B-17
ST.TM.E10100.1
B.6.3
Data Outputs
RS-232 Asynchronous (Low-speed) Data
This connector is located on the motherboard of the TT1260 Base Unit
(TT1260/DIRBAS).
Table B.23: RS-232 Asynchronous (Low-speed) Data Connector
Item
Specification
Safety status
SELV
Data-rates (bit/s)
1200; 2400; 4800; 9600; 19 200; 38 400
Standards
EIA RS-232C / ITU-T BT. V.24/V.28
Line length
< 15 metres
RS-422 Synchronous (High-speed) Data
This connector is located on the optional High Speed RS-422 Data Enabler
Card (TT1260/HWO/HSDATA).
Table B.24: RS-422 Synchronous (High-speed) Data Connector
Item
Specification
Safety status
SELV
Data-rates (bit/s)
Integer multiples of 56 Kbit/s and 64 Kbit/s up to 2.048 Mbit/s
Standards
EIA RS-422 / ITU-T V.11
Line length
< 1200 metres
B.6.4
Remote Control Connector
Table B.25: Control Connector
Item
Specification
Safety status
SELV
Connector type
9-way D-type, male
Connector designation
RCTRL RS-232/485
Standard
EIA RS-232C/RS-485