Appendix B: Automatic Measurements Reference

B- 18

CSA8000B & TDS8000B User Manual

Table B- 4: RZ Measurements - Amplitude (cont.)

Name

Definition

RZ Extinction Ratio (dB)

The ratio of the average power levels of the logic 1 level (High) to the logic 0 level (Low) of an
optical RZ signal, expressed in decibels, dB. All level determinations are made within the RZ
Eye Aperture.

Where High and Low are the logical 1 and 0 levels. See RZ Eye Aperture Parameters
on B--62.

The Eye Aperture is adjustable and defaults to 5% of the RZ pulse width.

If enabled, measurement gates constrain the measurement region to the area between the Start
Gate (G1) and Stop Gate (G2). See To Localize a Measurement on page 3--83.

This measurement requires the use of a waveform database. When this measurement is turned
on, it will automatically set the measurement system to use a waveform database if available.
See Use a Waveform Database on page B--70.

For best measurement results:

H Always perform a Dark Level compensation before taking this measurement. See To

Perform Dark-Level and User Wavelength Gain Compensations on page 3--98.

H Optimize the vertical resolution before taking this measurement. See To Optimize the

Vertical Resolution on page B--69.

RZ ExtRatio [dB]

= 10 × log

High

Low

RZ Eye Height

RZ Eye Height is a measure of how noise affects the vertical opening between the High and
Low levels of an RZ pulse. The RZ pulse is sampled within the Eye Aperture, where the High
and Low levels are determined as the mean of the histogram of the data distribution in the
upper and lower half of the pulse, respectively. The noise levels are characterized by

σhigh and

σlow, the standard deviations from the mean for the High and Low levels.

RZ Eye height = (High – 3 *

σhigh) – (Low + 3 * σlow),

Where High and Low are the logical 1 and 0 levels, and

σhigh and σlow are the standard

deviations.

The Eye Aperture is adjustable and defaults to 5% of the RZ pulse width.

If enabled, measurement gates constrain the measurement region to the area between the Start
Gate (G1) and Stop Gate (G2).

This measurement requires the use of a waveform database. When this measurement is turned
on, it will automatically set the measurement system to use a waveform database if available.

For best results with this measurement:

H Perform a Dark Level compensation before taking this measurement if the source of the

measured waveform is an optical channel. See To Perform Dark-Level and User
Wavelength Gain Compensations on page 3--98.

H Optimize the vertical resolution before taking this measurement. See To Optimize the

Vertical Resolution on page B--69.