Tektronix CSA8000B User Manual
Page 142
Displaying Waveforms
3- 68
CSA8000B & TDS8000B User Manual
Use the procedure that follows to become familiar with the display styles you
can set.
Overview
To set display styles
Related control elements and resources
Prerequisites 1.
The instrument must be powered up, with any waveform
you want to display on screen.
See page 3--24 for acquisition setup and
page 3--48 for trigger setup.
Access the
Display setup
dialog box
2.
From the application menu bar, select Setup, and then
select Display. See right.
Select normal
style, vectors,
and interpola-
tion
3.
From the Display Setup dialog box (see right) , choose
Normal to select a display with no acquisition data
persistence.
Waveforms display with the new data from ongoing
acquisitions replacing that data in the same time
intervals/slots but acquired as part of the last, previous
waveform.
4.
Check Vectors to turn on display lines between
waveform dots; uncheck to display only dots.
5.
Select an Interpolation mode from the pulldown list.
Choose from Sin(x)/x, Linear, or None.
Set Interpolation mode
Check for vectors
Check for normal display
To Set Display Styles