beautypg.com

Toshiba RKP004Z User Manual

Page 35

background image

11. Before making a service call

11-2

Problems

Possible causes

Remedies

Using a copy function is not
possible.

• APP-CPU and the LCD type

form may not be appropriate.

• When APP-CPU and the LCD type form

are not appropriate the copy function
cannot be used.

Memory data error message
is displayed.

• Something is wrong with the

internal memory.

• Copy to the LCD again. (ref. Chapter 8)

Disconnection error
message is displayed when
the copy function is used.

• Connection may be broken

during communication.

• Check the cable and the connector,

then copy again.

"TOSHIBA" screen is
momentarily displayed when
using copy function or the
confirmation of the memory
information.

• This phenomenon appears only

once when using copy function
for the first time.

• Does not appear after doing copy to the

LCD one time(ref. Chapter 8.1).

“----“ is displayed when using
the confirmation of the memor
information function.

• It occurs when LCD has no

information or communication
signal between LCD and the
inverter is disconnected while
copying to the LCD.

• Copy to the LCD. (ref. Chapter 8)

German cannot be selected. • APP-CPU version of VFAS1 is

less than V104.

• German can be selected by using

APP-CPU version of VFAS1 is V106 or
greater.