Toshiba RKP004Z User Manual
Page 10

1. Names and functions
1-3
About the change of parameter settings
By default, the inverter is set with parameters to the mode in which it controls the
operation of the machine via a terminal board. Moreover, the inverter is set so that
the switching between forward run and reverse run cannot be performed using its
operation panel.
To operate the inverter using this unit, parameter settings need to be changed, as
described below.
Parameter CMOd (Command input mode) =1 (Pane/LCD-option)
Parameter FMOd (Frequency input mode 1) =4 (Pane/LCD-option)
Parameter Fr (Panel FWD/REV selection) =2 (Forward (switchable)),
3 (Reverse (switchable))
This change of parameter settings makes it possible to start operation using the
[RUN] key, to stop operation using the [STOP/RESET] key, and to switch between
forward run and reverse run using the [FWD/REV] key.
Furthermore, it allows you to set an operation frequency using the control dial.
⇒ Refer to “5.1 Setting a panel operation frequency.”
- MK4007GAL (9 pages)
- DVD-ROM DRIVE SD-M1712 (16 pages)
- OIS40R (2 pages)
- IVP8 (71 pages)
- MK8016GSG (2 pages)
- Tecra 061215 (38 pages)
- G9 ETB006Z (1 page)
- SD-R2412 (12 pages)
- OIS50 (2 pages)
- PCX1000 (18 pages)
- MK6026GAX (11 pages)
- Entone 95-810500-00 (14 pages)
- SD-R1002 (16 pages)
- 512E (1 page)
- T2N (272 pages)
- MK3004GAH (9 pages)
- AR-B1375 (69 pages)
- AUXILIARY CABINET 431B (64 pages)
- MK1016GAP (11 pages)
- MK1234 (4 pages)
- A305 (3 pages)
- 1.8-INCH HARD DISK DRIVE MK6006GAH (9 pages)
- MK3006GAL (153 pages)
- AF 512E (2 pages)
- MK8007GAH (9 pages)
- BCN002Z (16 pages)
- DRIVE MK6022GAX (11 pages)
- MK2003GAH (9 pages)
- MK6006GAH (157 pages)
- XM-6802B (15 pages)
- Parani UD100 (1 page)
- V.90 (102 pages)
- MK4025GAS (11 pages)
- MK5002MPL (9 pages)
- SD-R1512 (17 pages)
- Rockbox F Series (177 pages)
- (HDD2188) (11 pages)
- Low Voltage Motors VR Series (2 pages)
- MK1214GAP (11 pages)
- SD-M2012C (16 pages)
- 480082-D0 (9 pages)
- SD-C2712 (12 pages)
- HDD2188 MK8025GAS (11 pages)
- Electromagnetic Flowmeter Converter TIC-LF232A (8 pages)
- P000233790 (53 pages)