7.12 SERIAL COMMUNICATION TEST SET-UP

Use the following instructions as basic set-up to test the serial communication operation.


1.Equipment: PC with Windows Hyper Terminal, software installed, Genesys

TM

Power supply, RS232 cable.

2. PC set-up: 2.1 Open Hyper Terminal……………………. New Connection.

2.2 Enter a name

2.3 Connect to………………………………… Direct to Com 1 or Com 2

2.4 Configure port properties:

Bits per second……9600

Data bits……………8

Parity……………….None

Stop bits……………1

Flow control……….None

2.5 Open Properties in the program

File………………….Properties

2.6 Setting: ASCII Set Up

Select Echo characters locally, select send line ends with line feed.
On some PC systems, pressing the number keypad “Enter” will dis-
tort displayed messages. Use the alphabetic “Enter” instead.


3. Power supply set-up:

3.1 Connect the power supply to the PC using the RS232 cable.

3.2 Set via the front panel: Baud Rate: 9600, Address: 06 (default).

3.3 Set via the rear panel: RS232/RS485 to RS232 (refer to Section 4-4).

4. Communication Test:

4.1 Model identification:

PC:write: ADR 06
Power supply response: “OK”

4.2 Command test:

PC write: OUT1
Power supply response: “OK”
PC write: PVn
Power supply response: “OK”
PC write: PCn (for values of n see Tables 7-4, 7-5 and 7-6)
Power supply response: “OK”


The power supply should turn on and the display will indicate the actual Output
Voltage and the actual Output Current.