beautypg.com

1 introduction, 2 front panel controls and indicators, The genesys – TDK GENESYS 750W HALF RACK User Manual

Page 35

background image

83-507-5002 Rev. B

27

CHAPTER 4 FRONT AND REAR PANEL CONTROLS AND CONNECTORS

4.1 INTRODUCTION

The Genesys

TM

Power Supply series has a full set of controls, indicators and connectors that al-

low the user to easily setup and operate the unit. Before starting to operate the unit, please read
the following Sections for explanation of the functions of the controls and connectors terminals.
-Section 4.2: Front Panel Controls and Indicators.
-Section 4.3: Rear Panel Connections and Controls.

4.2 FRONT PANEL CONTROLS AND INDICATORS

See Fig.4-1 to review the controls, indicators and meters located on the power supply front panel.

Table 4-1: Front Panel controls and indicators

Number

Control/Indicator

Description

Section

1

VOLTAGE
control

High resolution rotary encoder for adjusting the Out-
put Voltage. Also adjusts the OVP/UVL levels and
selects the Address

5.2.1
5.3.1
5.4.1
7.2.2

2

VOLTAGE
indicator

Green LED, lights for constant-Voltage mode opera-
tion.

3

VOLTAGE
display

4 digit, 7-segment LED display. Normally displays
the Output Voltage. When the PREV button is
pressed, the display indicates the programmed set-
ting of the Output Voltage. When the OVP/UVL but-
ton is pressed, the Voltage display indicates the
OVP/UVL setting.

Fig.4-1: Front panel controls and indicators

VOLTAGE

ALARM

FINE

PREV/

OVP

UVL

FOLD

REM/LOC

OUT

DC AMPS

CURRENT

DC VOLTS

POWER

1

14

17

18

19

2

15

16

3

13

10

4

11

5

12

9

6

7

8