Test if MD Mode is Installed

Send AA Hex followed by the address of the supply in binary. If not installed, the supply will re-
turn a ‘1’. If installed, the supply will return a ‘0’.

7.10.5 Addressed commands without response

7.10.5.1

Acknowledge SRQ

Send (0xE0 + Address) (1 byte binary - send 2 times sequentially). The supply will stop re-
sending SRQ. If Enable SRQ retransmission is active, it will remain active.

7.10.5.2

Re-enable SRQ with out reading/clearing the SEVE Register

Send A5 Hex followed by the address of the supply in binary and new SRQ’s generated by new
events in the Fault Event will be enabled without reading and clearing the Status Event Register.
All events previously recorded in the Fault Event Register must have been serviced by the user’s
software prior to this command to take effect.

Name

Bit Positions

Response

Description

Global

Commands

Disable MD Mode

1010 0000

None

Set supplies out of MD Mode (de-
fault)

Enable MD Mode

1010 0001

None

Set supplies into MD Mode

Disable SRQ

retransmission

1010 0010

None

Disable retransmission of SRQs
by supplies (default)

Enable SRQ

retransmission

1010 0011

None

Enable retransmission of SRQs by
supplies

Enable FLT Bit

1010 0100

None

Enable the FLT bit in the SENA
Register

Disconnect serial

communications

1011 1111

OK

All supplies will halt transmission
and enter the non-addressed
state.

Addressed

Commands

Read Registers

100x xxxx

Register data

Non destructive read of all regis-
ter. x xxxx is the address of the
supply in binary.

Re-enable SRQ

Byte 1

1010 0101

Byte 2

xxxx xxxx

None

Re-enable SRQ without reading or
clearing the SEVE Register. xxxx
xxxx is the address of the supply
in binary. Works only in MD Mode.