83-507-5002 Rev. B

56

7.8.3 Initialization Control Commands

#

Command

Description

1

ADR n

ADR is followed by address, which can be 0 to 30 and is used to access the
power supply.

2

CLS

Clear status. Sets FEVE and SEVE registers to zero (refer to Section 7-11).

3

RST

Reset command. Brings the power supply to a safe and known state:
Output voltage: zero, Remote: non-lockout remote,
Output current: zero, Auto-start: Off,
Output: Off, OVP: maximum,
FOLD: Off, UVL: zero
The conditional registers (FLT and STAT) are updated, the other registers
are not changed.

4

RMT

Sets the power supply to local or remote mode:
1. RMT 0 or RMT LOC, sets the power supply into Local mode.
2. RMT 1 or RMT REM, sets the unit into remote mode.

3.

RMT 2 or RMT LLO, sets the unit into Local Lockout mode (latched remote
mode).

5

RMT?

Returns to the Remote mode setting:
1. “LOC” - The unit is in Local mode.
2. “REM” - The unit is in Remote mode.
3. “LLO” - The unit is in Local Lockout (latched remote) mode.

6

MDAV?

Returns MD MODE OPTION Status. 1 indicates installed and 0 indicates not
installed.

7

\

Repeat last command. If \ is received, the power supply will repeat the
last command.

7.8.4 ID Control Commands

#

Command

Description

1

IDN?

Returns the power supply model identification as an ASCII string:

LAMBDA,

GENX-Y

2

REV?

Returns the software version as an ASCII string.

3

SN?

Returns the unit serial number. Up to 12 characters.

4

DATE?

Returns date of last test. Date format: yyyy/mm/dd

7.8.5 Output Control Commands

#

Command

Description

1

PV n

Sets the output voltage value in Volts. The range of voltage value is de-
scribed in Table 7-5. The maximum number of characters is 12. See the fol-
lowing examples for PV n format: PV 12, PV 012, PV 12.0, PV 012.00, etc…

2

PV?

Reads the output voltage setting. Returns the string “n” where “n” is the ex-
act string sent in the PV n command. When in Local mode, returns the
PREVIEW (front panel) settings in a 5 digit string.

3

MV?

Reads the actual output voltage. Returns a 5 digits string.
Example: 60V supply sends 01.150, 15.012, 50.000, etc…

4

PC n
(See
Note 1)

Set the Output Current value in Amperes. The range of current values is de-
scribed in Table 7.6. The maximum number of characters is 12. See the fol-
lowing examples for PC n format: PC n format: PC 10, PC 10.0, PC 010.00,
etc…

5

PC?

Reads the Output Current setting. Returns the string “n” where “n” is the ex-
act string sent in the PC n command. When in Local mode, returns the
PREVIEW (front panel) settings in a 5 digit string.