10 N OMWT-SOFT-OPC Main Window
OMWT-SOFT-OPC Server
View IP Connection Status
(OMWT-RECIP Receiver only)
OWMT-SOFT-OPC will display the “IP Status” screen. OWMT-SOFT-OPC shows
the current state of the all the connections. The following describes the columns:
Node – Node number for the IP address. OWMT-SOFT-OPC uses this
number to identify this IP connection. OWMT-SOFT-OPC uses this
number to update the OPC item “nodaladdress”.
IP Address – the IP address that is used to address the receiver.
Port – the port number that is used along with the IP address to address the
receiver.
Conn – identifies who initiated the connection. Outgoing: OWMT-SOFT-
OPC initiated the connection with the receiver. Incoming: the receiver
initiated the connection with OWMT-SOFT-OPC.
Description – a general description field associated with the IP connection.
Status – the current status of the connection. The following is a list of the
possible status messages:
Never Connected – OWMT-SOFT-OPC never attempted or received a
connection to the receiver
IP Connected – OWMT-SOFT-OPC is currently connected to the
receiver but has not logged in.
Connected – OWMT-SOFT-OPC is currently connected to the receiver
is waiting to receive sensor packets.
Disconnected – OWMT-SOFT-OPC was connected but is now
disconnected from the receiver. If the connection was initiated by
OWMT-SOFT-OPC, OWMT-SOFT-OPC will continually try to
reestablish the connection.
TCP/IP Error – a TCP/IP error was encounter and OWMT-SOFT-OPC
is not connected to the receiver.
No IP Connection – OWMT-SOFT-OPC tried to establish a connection
but failed.
Wrong Password – The receiver requires a login password and the
incorrect password was used by OWMT-SOFT-OPC.