Raritan Computer SX User Manual
Page 153
C
HAPTER
12:
C
OMMAND
L
INE
I
NTERFACE
135
<command>
raw – Send a RAW IPMI request and print response
i2c – Send an I2C Master Write-Read command and print response
lan – Configure LAN Channels
chassis – Get chassis status and set power state
power – Shortcut to chassis power commands
event – Send pre-defined events to MC
mc – Management Controller status and global enables
sdr – Print Sensor Data Repository entries and readings
sensor – Print detailed sensor information
fru – Print built-in FRU and scan SDR for FRU locators
sel – Print System Event Log (SEL)
pef – Configure Platform Event Filtering (PEF)
sol – Configure and connect IPMIv2.0 Serial-over-LAN
tsol – Configure and connect with Tyan IPMIv1.5 Serial-over-LAN
isol – Configure IPMIv1.5 Serial-over-LAN
user – Configure Management Controller users
channel – Configure Management Controller channels
session – Print session information
firewall – Configure firmware firewall (IPMIv2.0)
sunoem – OEM Commands for Sun servers
picmg – Run a PICMG/ATCA extended cmd
fwum – Update IPMC using Kontron OEM Firmware Update Manager
shell – Launch interactive IPMI shell
exec – Run list of commands from file
set – Set runtime variable for shell and exec
Command Example
The following command allows the user to get the chassis status and set the power state.
admin> IPMI > ipmitool -I lan -H 10.0.22.7 -U ADMIN chassis status
Password:
System Power : on
Power Overload : false
Power Interlock : inactive
Main Power Fault : false
Power Control Fault : false
Power Restore Policy : always-off
Last Power Event : command
Chassis Intrusion : active
Front-Panel Lockout : inactive
Drive Fault : false
Cooling/Fan Fault : false
For additional information: refer to