beautypg.com

Raritan Computer SX User Manual

Page 153

background image

C

HAPTER

12:

C

OMMAND

L

INE

I

NTERFACE

135

<command>

raw – Send a RAW IPMI request and print response
i2c – Send an I2C Master Write-Read command and print response
lan – Configure LAN Channels
chassis – Get chassis status and set power state
power – Shortcut to chassis power commands
event – Send pre-defined events to MC
mc – Management Controller status and global enables
sdr – Print Sensor Data Repository entries and readings
sensor – Print detailed sensor information
fru – Print built-in FRU and scan SDR for FRU locators
sel – Print System Event Log (SEL)
pef – Configure Platform Event Filtering (PEF)
sol – Configure and connect IPMIv2.0 Serial-over-LAN
tsol – Configure and connect with Tyan IPMIv1.5 Serial-over-LAN
isol – Configure IPMIv1.5 Serial-over-LAN
user – Configure Management Controller users
channel – Configure Management Controller channels
session – Print session information
firewall – Configure firmware firewall (IPMIv2.0)
sunoem – OEM Commands for Sun servers
picmg – Run a PICMG/ATCA extended cmd
fwum – Update IPMC using Kontron OEM Firmware Update Manager
shell – Launch interactive IPMI shell
exec – Run list of commands from file
set – Set runtime variable for shell and exec

Command Example

The following command allows the user to get the chassis status and set the power state.

admin> IPMI > ipmitool -I lan -H 10.0.22.7 -U ADMIN chassis status


Password:

System Power : on

Power Overload : false

Power Interlock : inactive

Main Power Fault : false

Power Control Fault : false

Power Restore Policy : always-off

Last Power Event : command

Chassis Intrusion : active

Front-Panel Lockout : inactive

Drive Fault : false

Cooling/Fan Fault : false


For additional information: refer to

http://ipmitool.sourceforge.net/manpage.html