RAD Data comm ASMi-52 User Manual
Page 117

Installation and Operation Manual
Chapter 6 Troubleshooting and Diagnostics
ASMi-52 Ver. 2.5
Handling Alarms
6-13
Table 6-3. ASMi-52 Alarms and Warnings (Cont.)
Number Terminal
Message
Port
Description
Severity
32
E1 EXCESIVE ERR
RATIO
T1 EXCESIVE ERR
RATIO
DTE
The bit error rate of the link exceeds 10
-3
Major
33
E1 AIS OCCURED
T1 AIS OCCURED
DTE
AIS is detected at the E1 or T1 port
Major
34
E1 AIS AND SYNC
LOSS
T1 AIS AND SYNC
LOSS
DTE
AIS and loss of frame alignment are detected at
the E1 or T1 port
Major
35 E1
SYNC
LOSS
T1 SYNC LOSS
DTE
E1 or T1 loss of frame synchronization occurred
Major
36
E1 CRC MF EXC
DTE
CRC errors detected in the frame synchronization
signal exceeded the threshold
Minor
37
E1 REMOTE SYNC
LOSS
T1 REMOTE SYNC
LOSS
DTE
Remote loss of frame synchronization occurred
Major
38
E1 MF SYNC LOSS
DTE
Local loss of frame synchronization
Major
39
E1 MF REMOTE SYNC
LOSS
DTE
Remote loss of frame synchronization
Major
40
E1 TS NOT X128
T1 TS NOT X128
DTE
Number of timeslots assigned for the ASMi-52
unit with 4-wire line interface is not n×128
Major
41
E1 TS NOT COMP
T1 TS NOT COMP
DTE
Number of timeslots assigned for the local unit
does not match the number of timeslots assigned
for the remote unit.
Major
42 WIRE
MODE
NOT
COMP
SHDSL
Mismatch between line interface types (2/4-wire)
between local and remote units
Major
43
SPAN IS NOT FULL
SHDSL
The distance between adjacent repeaters is too
long. You can identify the problematic segment
by checking the Port Status screen. In the
Number of Repeaters line, it displays the last
repeater identified by ASMi-52. This means that
the distance between the last detected repeater
and the next repeater exceeds its maximum
range.
Major
44 LOOP
ATTN.
OVER
NETWORK SIDE
SHDSL
Loop attenuation at the network side of the
repeater has exceeded the alarm threshold
Major