Connecting to Other Devices

When you have a MIDI sequencer connected, set this parameter to
Local Off.

Since the Thru function of your sequencer will normally be turned
on, notes played on the keyboard or played back by the recorder
will be transmitted to the sound generator by the two routes (1) and
(2) shown in the illustration, causing notes

to be sounded in duplicate or to be cut off unnaturally. To prevent
this, the setting called “Local Off” is used to disconnect the route in
(1).

fig.aaaa

Local On:

The keyboard and recorder are connected to the internal sound
generator.

fig.aaaa

Local Off:

The keyboard and recorder are not connected to the internal sound
generator. No sound will be produced by the keyboard when it is
played.

fig.aaaa

1.

Enter Function mode, choose “L. Ct”(p. 55).

2.

Press the [-] or [+] button to switch “On” or “OFF.”

This setting specifies the MIDI channel on which the HP305/HP302

will transmit. MIDI uses sixteen “MIDI channels,” which are

numbered 1 through 16. By connecting MIDI devices and specifying

the appropriate MIDI channel for each device, you can play or select

sounds on those devices.

The HP305/HP302 will receive all sixteen channels (1–16).

1.

Enter Function mode, choose “Ch” (p. 55).

2.

Press the [-] or [+] button to edit the setting.

When set to “OFF,” none of the data describing what you play

on the keyboard will be transmitted.

When Composer MIDI Out is “On,” you can send performance data

recorded with the HP305/HP302 to a connected MIDI device or

computer.

1.

Enter Function mode, choose “Out”(p. 55).

2.

Press the [-] or [+] button to switch “On” or “OFF.”

Preventing Doubled Notes When
Connected to a Sequencer (Local Control)

(1)

MIDI

MIDI

MIDI

MIDI

(2)

IN

IN

OUT

OUT

Sequencer

Memory

Sound

Generator

Each note played is sounded twice

Soft Thru On

Local On

Local On

Sound is emitted

Sound Generator

Local Off

No sound produced

Sound Generator

Setting

Description

On

The Local Control is set to On.
The keyboard and recorder are connected to the internal
sound generator.

OFF

The Local Control is set to Off.
The keyboard and recorder are not connected to the internal
sound generator. Playing the keyboard or playing back a song
will not produce sound.

MIDI Transmit Channel Settings
(MIDI Transmit Channel)

Setting (Channel)

OFF, 1–16

Sending Recorded Performance Data to a
MIDI Device (Composer MIDI Out)

Setting

Description

On

Performance data is transmitted.

OFF

Performance data is not transmitted.