CONFIG Commands
SNMP Notify Type Settings
SNMP Notify Type is suppor ted beginning with Firmware Version 7.4.2.
set snmp notify type [ v1-trap | v2-trap | inform ]
Sets the type of SNMP notifications that the system will generate:
•
v1-trap – This selection will generate notifications containing an SNMPv1 Trap Protocol
Data Unit (PDU)
•
v2-trap – This selection will generate notifications containing an SNMPv2 Trap PDU
•
inform – This selection will generate notifications containing an SNMPv2 InformRe-
quest PDU.
System Settings
You can configure system settings to assign a name to your Netopia Gateway and to spec-
ify what types of messages you want the diagnostic log to record.
set system name
name
Specifies the name of your Netopia Gateway. Each Netopia Gateway is assigned a name as
par t of its factor y initialization. The default name for a Netopia Gateway consists of the
word “Netopia-3000/XXX” where “XXX” is the serial number of the device; for example,
Netopia-3000/9437188. A system name can be 1 – 255 characters long. Once you have
assigned a name to your Netopia Gateway, you can enter that name in the Address text field
of your browser to open a connection to your Netopia Gateway.
☛
NOTE:
Some broadband cable-oriented Ser vice Providers use the
System Name as
an impor tant identification and suppor t parameter. If your Gateway is par t of
this type of network, do
NOT alter the System Name unless specifically
instructed by your Ser vice Provider.