Installing the server and connecting the peripheral devices

Standard 1.0

72

CallPilot

2 Connect the other end of the DC power cable to the Power Distribution

Unit (PDU). See details below:

The following photograph shows the keyed plug of the DC power cable.
This plug connects to the PDU:

Note: If you are not using a Nortel Networks-supplied PDU, snip this
plug and connect the cable appropriately to your DC power plant.
Remember that a red cable is positive, a black cable is negative, and a
green cable is the ground.

3 Turn on the PDU.

To start the server

1 Press the server’s power switch to start the server.

2 Observe the Power-On Self-Test (POST) and initialization messages on

the monitor.

3 When the following menu appears on the monitor, select option 1 to boot

Windows NT:

Select one of the following:

---------------------------

1 Windows NT 4.0 Server (Default within 30 secs)

2 Windows NT 4.0 Server (VGA mode)

Choose an option[1,2]?1

The Windows NT startup sequence begins.

4 Ensure that the Windows NT logon window appears on the monitor.

Note: If the Windows NT logon window does not appear, refer to Part 5
of the CallPilot Installation and Configuration binder for troubleshooting
instructions.