beautypg.com

Polycom 1 User Manual

Page 35

background image

Networks

2 - 21

4.

Select

and configure these settings:

5.

Select

and configure these settings:

Setting

Description

ST

Lets you specify the signaling required by the external
device connected to the system. Specify normal or
inverted, as appropriate. In most cases, normal signaling
is appropriate.

RT

RTS

CTS

If your system is connected to Ascend equipment, you
may need to set CTS to Ignore.

DSR

DCD

DTR

Answer on DSR

Specifies that the system should begin the call when it
detects a DSR signal.

Delayed DCD
Hangup

Specifies how long the system waits to end the call after
a DCD signal is lost (for example, during a call via
satellite).

DTR Pulse Duration
(secs)

Specifies how long the DTR signal goes low after the far
site hangs up. When the pulse is too short, the call may
not clear.
If your system is connected to ADTRAN equipment, you
may need to adjust DTR pulse duration.

Trigger Call on H.320
Data

Specifies whether the call starts when H.320 data is
detected at the V.35 interface while set for direct
connect.

Setting

Description

Crypto Resync

Allows a Polycom HDX system connected to
cryptographic equipment to signal when it loses video
synchronization during a call. The cryptographic
equipment can then resynchronize with the far site.

Use RTS Signal for
Resync Pulse

Allows the system to send the resynchronization pulse on
the RTS signal. Select this setting if your data
communications equipment uses the V.35 or RS-449
capability of the serial V.35/RS-449/RS-530 network
interface.
Note: When you select this setting, the RTS no longer
functions as the Request To Send signal.

Time Between
Pulses (sec)

Specifies whether the system should set the time
between resync pulses automatically or use the number
of seconds you enter.