Select 10 cpi, Select 12 cpi, Select 15 cpi – Printronix P7000 H-Series User Manual
Page 51
Select 10 CPI
51
Select 10 CPI
ASCII Code ESC P
Hex Code
1B 50
Dec Code 27
80
Purpose
Selects 10-cpi character pitch.
Comment
If you change the fixed-pitch setting with this command during
proportional mode (selected with the ESC p command), the
change takes effect when the printer exits proportional mode.
This command affects “Select CPI” on the front panel.
This command takes effect only in SBCS mode.
Select 12 CPI
ASCII Code ESC M
Hex Code
1B 4D
Dec Code 27
77
Purpose
Selects 12-cpi character pitch.
Comment
If you change the fixed-pitch setting with this command during
proportional mode (selected with the ESC p command), the
change takes effect when the printer exits proportional mode.
This command affects “Select CPI” on the front panel.
This command takes effect only in SBCS mode.
Select 15 CPI
ASCII Code ESC g
Hex Code
1B 67
Dec Code 27
103
Purpose
Selects 15-cpi character pitch.
Comment
If you change the fixed-pitch setting with this command during
proportional mode (selected with the ESC p command), the
change takes effect when the printer exits proportional mode.
Characters from 0x80 to 0xFE cannot be printed in this mode.
This command affects “Select CPI” on the front panel.
This command takes effect only in SBCS mode.