52141: SoundStation IP 7000: daisy Chained phone sometimes gets
„stuck‟ during software upgrade.
Workaround: Pressing any key on the phone will continue the upgrade.
52142: VVX 1500, Video Interoperability: Video connections with
CounterPath Eyebeam client do not work if H.263-1998 codec is
selected. Experienced with Eyebeam version 1.5.19.5 build 52345.
Workaround: use a different codec. Try other versions of Eyebeam client
(some do work okay).
53514: VVX 1500, Video Interoperability: MGC50: H.264 calls to an
HDX9002 device using an MGC 50 Gateway using H.320 result in lip
sync. issues.
Workaround: Set the call for transcoding on the MGC.
54027: SRTP: The receiving phone does not re-invite with a new key at
the half life of the key life-time.
Workaround: Ensure that both ends use the same key life time such that the
sending phone will initiate a key re-negotiation.
54028: SRTP: Key Changes do not function correctly when multiple
crypto suites are enabled.
Workaround: Configure a single crypto suite on the phone.
54321: VVX 1500, Video Interoperability: VVX 1500 does not receive
video (does receive audio) when calls are initiated from a Tandberg C20
(running 2.0.0.191232) device using SIP.
Workaround: None.
54799: VVX 1500, Video Interoperability: VVX 1500 transmits H.264 QCIF
video to Tandberg MXPs in H.323 calls.
Workaround: Set the video bit rate on the VVX 1500 to 512kbps to avoid
the issue.
54976: VVX 1500, Video Interoperability: Tandberg: H.264 calls to a
Tandberg Edge95 MXP device using a Tandberg Gateway using
encrypted media (offered but not required) results in distorted audio
and no video on the VVX 1500.
Workaround: Configure system for encryption required.
54977: VVX 1500, Video Interoperability: Tandberg: H.264 calls to a
Tandberg Edge95 MXP device using a Tandberg Gateway result in lip
sync. issues.
Workaround: None.
59773: SoundPoint IP 550, 650: Phone locks and resets when answering
13
th
incoming call.
Workaround: Set the number of calls per line to less than 13.
59812: SoundStation IP 7000: Blind transfer to a URL is not successful.
Eventually, the URL soft key becomes unavailable.
Workaround: None.
61091:
The configuration parameter “tcpIpApp.port.rtp.forceSend =
1024” works only for the SoundStation IP 6000, 7000 and VVX 1500. It