1. Network Management Specification

52

June 2003

8000-A2-GB30-00

6.5

ATM Loopback

pdnATMfM4VcLoopbackTestTable in pdn_atmM4Ext.mib is supported to provide detailed
test results on ATM F5 loopback test. This tabular object augments atmfM4VcTestTable
(see Section 3.15).

In order to distinguish a single-cell loopback test from a multi-cell loopback test, In
addition to ATM Forum M4 Test Types atmfM4VcTestOAMLoopbackSeg and
atmfM4VcTestOAMLoopbackE2E, which indicate a single-cell loopback test, two new
test commands pdnATMfM4TestOAMLoopbackSegMultiCell and
pdnATMfM4VcTestOAMloopbackE2EMultiCell are defined to stop but not dealloc the
ATM F5 loopback test resource (such as result).

In order to initiate an ATM F5 Segment loopback test, an NMS must first obtain
‘ownership’ of the entry in the atmfM4VcTestTable for the VCC or VCL to be tested. This
is accomplished with atmfM4VcTestId and atmfM4VcTestStatus object as follows:

try_again:

get (atmfM4VcTestId, atmfM4VcTestStatus)
while (atmfM4TestStatus != notInUse)

/* Loop while a test is running or some other

* manager is configuring a test.
*/
short delay

pdnATMVclCurrEntry

(pdn_ATMStats.mib)

Yes

pdnATMVclCurrElapsedTime

Gauge32

Read-Only

pdnATMVclCurrTotalCellIns

Gauge32

Read-Only

pdnATMVclCurrTotalInDiscards

Gauge32

n

pdnATMVclCurrTotalCellOuts

Gauge32

Read-Only

pdnATMVclCurrTotalOutDiscards

Gauge32

Read-Only

pdnATMVclHistEntry

(pdn_ATMStats.mib)

pdnATMVclHistIndex

INTEGER

Read-Only

pdnATMVclHistElapsedTime

TimeInterval

Read-Only

pdnATMVclHistTotalCellIns

Gauge32

Read-Only

pdnATMVclHistTotalInDiscards

Gauge32

n

pdnATMVclHistTotalCellOuts

Gauge32

Read-Only

pdnATMVclHistTotalOutDiscards

Gauge32

Read-Only

Table 1-56. Paradyne Extensions to ATM MIBs (2 of 2)

Table

Object

Type

Sup-
ported

Table 1-57. ATM Loopback

Table

Comments

pdnATMfM4VcLoopbackTestEntry

Supported as is