SpectraLink 8002 Wireless Telephones Configuration and Administration (SIP)
80
PN: 1725-36034-001_B.doc
The table below lists the syslog messages and which level of logging
will produce them:
Message type
Errors
Events
Full
Failed
Handoff
Yes Yes Yes
Successful Handoff
No
Yes
Yes
Security
Error
Yes Yes Yes
Call Start/End
No
Yes
Yes
Audio stats
No
No
Yes (every 5 secs)
Audio error threshold exceeded Yes
Yes
Yes
Radio stats
No
No
Yes (every 5 secs)
Radio error threshold exceeded Yes
Yes
Yes
All syslog messages will include:
•
Date and time (to 1/100th of second) since handset power on
(currently set to Jan-1 00:00.00)
•
Handset’s MAC address
•
Handset’s IP address
•
Syslog sequence number
The table below lists the additional items in each message type:
Failed Handoff
(Sent whenever the handset attempted to
handoff, but failed trying.)
Failed AP MAC
Failed AP signal strength
Current AP MAC
Current AP signal strength
Failure reason
Successful Handoff
New AP MAC
New AP signal strength
Old AP MAC
Old AP signal strength
Reason for handoff
Other candidate APs:
MAC
Signal strength
Reason not used
Security Error
AP MAC
AP signal strength
Security mode
Error details (mode dependent)