Configuration Option Tables

A-14

7984-A2-GB20-10

February 1999

Table A-6.

Communication Protocol Options (1 of 2)

Node IP Address

Possible Settings: 000.000.000.000223.255.255.255
Default Setting: 000.000.000.000

Specifies the Node IP address.

H

Node IP Address is only available when the standalone unit is configured as an
LTU.

Address Field(000.000.000.000223.255.255.255) – Enter an IP address for the
node. The range for the first byte is 000 to 223, with the exception of 127. The range for
the remaining three bytes is 000 to 255.

Clear – Clears the IP address field and sets to all zeros.

Node Subnet Mask

Possible Settings: 000.000.000.000255.255.255.255
Default Setting: 000.000.000.000

Specifies the Node Subnet Mask.

H

Node Subnet Mask is only available when the standalone unit is configured as an
LTU.

Address Field(000.000.000.000255.255.255.255) – Enter an address for the
Node Subnet Mask.

Clear – Clears the address field and sets to all zeros.

Default Network Destination

Possible Settings: None, COM, DSL
Default Setting: None

Specifies where the default management network is connected. For example, if your
default network is connected to the COM port, select COM as the default management
network destination.

None – No default destination is defined. Data that cannot be routed is discarded.

COM – The unit’s COM port is the default network destination.

H

COM is only available when the Port Use option on the Communication Port
Options menu is set to Net Link.

DSL – The unit’s DSL port is the default network destination.

Communication Port IP Address

Possible Settings: 000.000.000.000223.255.255.255
Default Setting: 000.000.000.000

Specifies the unit’s Communication Port IP Address when the unit is configured as a
network communication link.

H

Communication Port IP Address is only used when the Port Use option on the
Communication Port Options menu is set to Net Link. If the COM Port IP address
is not set (000.000.000.000) the node IP address specified by the Node IP Port
will be used.

Address Field (000.000.000.000223.255.255.255) – Enter an IP address for the
Communication Port. The range for the first byte is 000 to 223, with the exception of
127. The range for the remaining three bytes is 000 to 255.

Clear – Clears the IP address and sets to all zeros.