System options menu, System options, Table a-3 – Paradyne M/HDSL Standalone Termination Unit Hotwire 7984 User Manual
Page 86: Able a-3, And t, Appendix a, Configuration option t
Configuration Option Tables
A-6
7984-A2-GB20-10
February 1999
System Options Menu
For System Options, refer to Table A-3. To access the System Options screen,
follow this menu selection sequence:
Main Menu
→
Configuration
→
Load Configuration From
→
System
О
О
ОО
ОО
main/config/system
Hotwire
Model: 7984
SYSTEM OPTIONS
DSL Mode:
NTU
Test Timeout:
Enable
Test Duration (min):
10
Telco Initiated Loopback:
Enable
Remote Telco Line Loopback:
Disable
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Ctrl-a to access these functions, ESC for previous menu
MainMenu
Exit
Save
Table A-3.
System Options (1 of 2)
DSL Mode
Possible Settings: LTU, NTU
Default Setting: NTU
Controls whether the unit is configured as a control unit or tributary unit.
LTU – The unit is configured as a control unit (Line Termination Unit).
NTU – The unit is configured as a tributary unit (Network Termination Unit). This unit will
request its IP address from the LTU during establishment of the PPP link.
NOTE:
Changing this option will reset the card.
Test Timeout
Possible Settings: Enable, Disable
Default Setting: Enable
Allows tests to end automatically. The feature should be enabled when the unit is
remotely managed, so that control can be regained after a test is accidentally executed.
Enable – Loopback and pattern tests end when test duration is reached.
Disable – Tests run until manually terminated from the Network Tests screen or
remotely (network initiated tests). Refer to
Testing.
Test Duration (min)
Possible Settings: 1–120
Default Setting: 10
Number of minutes for a test to be active before automatically ending.
H
Test Duration (min) appears when Test Timeout is enabled.
1 to 120 – Amount of time in minutes for a test runs before terminating.