Self-Test Results

The results of the last power-up or reset self-test appear in the middle column of
the System and Test Status screen.

Table 4-2.

Self-Test Results Messages

Message

What Message Indicates

What To Do

CPU Failed

The CPU failed internal testing.

1. Reset the unit and try again.

Device
Failed

One or more of the Unit’s integrated
circuit chips failed device-level
testing.

2. Call your service

representative for assistance.

DSX-1
Failed, Pt 1

The Unit failed to loop data on the
DSX-1 interface on Port 1.

1. Reset the unit and try again.

2. Call your service

Memory
Failed

The 7984 Standalone Termination
Unit failed memory verification.

2. Call your service

representative for assistance.

FPGA
Failed, Pt1

A failure in the FPGA was detected.

1. Reset the unit and try again.

2. Call your service

representative for assistance.

DataPath
Failed, Pt1

The unit failed to loop data between
the DSX-1 Port and the DSL loop.

1. Reset the unit and try again.

2. Call your service

representative for assistance.

Failure
xxxxxxxx

An internal failure occurred.
(xxxxxxxx represents an 8-digit
hexadecimal failure code for use by
service personnel.)

Record the failure code and
contact your service
representative.

Passed

No errors were detected.