Switchpack Definitions

Manually change configuration options by moving Switchpack S1 DIP switches
on the card. Table 3-1 lists Switchpack S1 definitions.

Table 3-1.

Switchpack S1 Definitions

Switch # . . .

Allows you to . . .

Default in Bold

1

Enable or disable Switchpacks S1 and S2.

OFF = Switchpacks Disabled
ON = Switchpacks Enabled

2

Not used

3

Select the unit’s primary timing source. Only valid for units configured
as LTU.

OFF = Internal Clock
ON = External Clock

4

Control the unit’s T1 line coding.

OFF = B8ZS
ON = AMI

5

Control the unit’s framing format

OFF = ESF
ON = D4

6, 7, 8

Control the unit’s equalization. The three switches form a binary value
used as an index to the table of equalization values. Off denotes 0 and
On denotes 1.

000 = 0–133 feet
001 = 133–266 feet
010 = 266–399 feet
011 = 399–533 feet
100 = 533–655 feet
101 = 0–133 feet
110 = 0–133 feet
111 = 0–133 feet