3.2 SOFTWARE CONFIGURATION
The NetLink-T1™ features a menu-driven command system that allows
you to monitor/conÞgure its operating parameters. Follow the instruc-
tions below to conÞgure the Model 2710 using the software switches:
1. Plug the 9-pin male end of the cable to your terminal or computer’s
DB-9 serial port and start up the terminal emulator software if nec-
essary. Plug the miniature stereo plug into the rear of the unit. The
small recessed jack on the right side of the unit is the control port
jack.
Note
If your terminal uses a DB-25 connector, please use a DB-9 to
DB-25 Adapter to connect to the cable (See Model 18PC-M).
2. Power up the terminal and set its RS-232 port as follows:
9600 Baud
8 data bits, 1 stop bit, no parity
Local echo off
ANSI or VT-100 emulation
3. Here is an example of a terminal emulator setup session. In normal
font are the various parameter types. In bold type are the values that
should be used for best results. Your terminal program’s setup
screen may differ from this one:
4. When the unit is Þrst turned on, the terminal screen may appear
blank. Press the
the unit will immediately display a password prompt.
5. Type in the password and press
word for the unit is:
patton
.
Note
If the entry is incorrect, the password screen will clear and
prompt you again for the correct password. The password you
Baud Rate:
9600
Parity:
None
Data Length:
8
Stop Bits:
1
Default terminal type:
VT100
Local Echo:
OFF
Add Line Feeds after CRs:
OFF
Received Backspace Destructive:
ON
Backspace key sends:
BS
XON/XOFF software ßow control:
ON
CTS/RTS hardware ßow control:
OFF
DSR/DTR hardware ßow control:
OFF