Integrators’ Reference Manual for ViewStation EX, ViewStation FX, and VS4000

64

www.polycom.com

The PRI T1 needs to be provisioned for the ViewStation FX and
VS4000 systems as follows:

Table 3-4. ISDN PRI Requirements

Line settings

ESF/B8ZS (default)

Extended Super Frame B8ZS is modem standard for
T1/PRI line encoding and framing

Line termination
type

CPE (user side) only

The required termination is built into the system and
most access switches

Supported PRI
switch protocols

AT&T 4ESS, AT&T 5ESS, NI-1, NI-2, Siemens,
Nortel DMS 100, and Nortel 250

These are standard protocols for North America

Number of
channels

23 B-channels dialable at 64 or 56 Kbps, and one D
channel

Ensure that you have 64 Kbps clear channel service

Number of
network
interfaces

1 (single PRI)

Line build-out
modes

DSU+CSU (0 to –22.5dB attenuation), DSU-only
(DSX 0-665 feet)

Physical distance is offset by the settings in the user
interface

Clocking

Must be derived from the external network or the
PBX

Terminal
Endpoint ID
(TEI)

0-63

This identifies the PRI endpoint; the common default
is 0

Numbering

One local directory number per interface (23
channels)

D-channel slot
number

24

Included to verify where the D channel is; this is
where additional diagnostic information resides

Call-by-call
service codes

Values 0-31 service codes for GVPN/PN/UPN
network-specific services