Chapter 6 - Testing and Troubleshooting

© Polycom, Inc.

117

69

Requested
facility not
implemented

The remote equipment is not capable of
providing the requested supplementary
service.

70

Only restricted
digital
information
bearer is
available

The network is unable to provide
unrestricted digital information over bearer
capability.

79

Service or
option not
available,
unspecified

The network or remote equipment is unable
to provided the requested service option for
an unspecified reason. This might be a
subscription problem.

81

Invalid call
reference value

The remote equipment received a call with a
call reference that is not currently in use on
the user-network interface.

82

Identified
channel does
not exist

The receiving equipment is requested to use
a channel that is not activated on the
interface for calls.

83

A suspended
call exists but
this call identity
does not

The network received a call resume request
that contained a call identity information
element that does not match any suspended
call.

84

Call identity in
use

The network received a call suspend
request that contained a call identity
information element for a call that is already
suspended.

85

No call
suspended

The network received a call resume request
when there was not a suspended call
pending. This might be a transient error that
will be resolved by successive call retries.

86

Call having
requested call
identity has
been cleared

The network received a call resume request
containing a call identity information
element for a call that was cleared while
suspended, either by timeout or by the
remote user.

88

Incompatible
destination

Indicates that an attempt was made to
connect to non-ISDN equipment, such as an
analog line.

Table 6-7. ISDN Call Status Codes (Continued)

Code

Cause

Definition