beautypg.com

Polycom ViewStation EX4000 User Manual

Page 52

background image

Integrators’ Reference Manual for ViewStation EX, ViewStation FX, and VS4000

42

www.polycom.com

Table 2-24. Non-Dialed User-Initiated Call State Machine

State

ViewStation FX or
VS4000 Signals

Network Signals

1

Initial State:
DTR = 0

a

RTS = 0

b

CRQ = 0

a. DTR does not act as shown but remains high if DTR is set to ON
in the V.35 Advanced Setup screen.

b. RTS does not act as shown but acts as a resync pulse if
Security/Crypto Resync is set to ON.

Initial State:
RI = 0
DLO = 0
ACR = 0
DSR = 0

USER INITIATES
CALL

2

DTR = 1

a

3

RTS = 1

b

4

DCD = 0 to 1

5

DATA FLOW STARTS

DATA FLOW STARTS

User Hang-up

Far end hang-up

6

RTS = 0

b

DTR = 0

a

CRQ = 0

All signals go low if far
end or User hang up is
detected

DSR= 1 to 0, OR
DCD= 1 to 0

A falling edge on DSR
or DCD is interpreted
by the FX/ VS4000 as
a hang-up

c

c. If DCD filter is set to ON in the V.35 Advanced Setup screen,
the system does not react to a low DCD until DCD has been low
for 60 seconds.

7

IDLE
DTR = 0

a

RTS = 0

b

CRQ = 0

IDLE
RI = 0
DLO = 0
ACR = 0
DSR = 0