Configure the System for RS-232 Operation

To configure your system to use the RS-232 interface:

1.

Select System Info > Admin Setup > Software/Hardware >
RS-232

to display the RS-232 screen

2.

Configure the Baud Rate.

3.

Configure the RS-232 Mode. Select Control Mode to allow the
system to act as a slave device under the control of the RS-232
device using the Remote Control API, or select Pass-Thru Mode
to do either of these:

Allow the system to act as a master device, controlling the
ViewStation EX, ViewStation FX, or VS4000 at the far end.

Configure the system as a null-modem, using the RS-232
port as a data channel.

4.

Configure Flow Control.

Command Line Interface (CLI)

Several communications programs (such as HyperTerminal) are
available to provide a command line interface (CLI) to control the
system via the RS-232 interface. The following explains how to start
a HyperTerminal session on your PC.

To start a HyperTerminal session:

1.

From your PC desktop, select Start > Programs > Accessories >
Communications > HyperTerminal

.

2.

In the Connection Description window, enter a Name. Select
an icon. Click OK.

3.

In the Connect To window, from the Connect Using list, select
the proper comport (usually com1). Click OK.