beautypg.com

Print module replacement / height adjustment – Paxar 545 User Manual

Page 58

background image

56

Maintenance

Users Manual Model 545™

Print Module Replacement / Height Adjustment

CAUTION: Turn off the power to the printer before removing or inserting the

print module(s).

DUE TO THE TOLERANCES IN THE PRINT MODULES AND OF THE

PRINT HEADS THEMSELVES, THE ENTIRE PRINT MODULE MUST
BE REPLACED - ONCE A PRINT HEAD HAS REACHED ITS END OF
LIFE.

1) Remove the ink cartridge from the printer in order to remove the print module.

2) Remove the print module by holding the release lever to the right and lifting the

print module from the printer using its handle.

3) Insert a replacement print module in the reverse order.

4) If the replacement print module does not function properly by swinging the print

heads out to the print position, the module stop block may need to be adjusted.
These stop blocks are located beneath the print module under the front nose
cover of the machine. With the power off remove the cover by removing four
screws, two on either end of the cover then while holding the active unwind
pinch roller down slide the cover forward far enough to unplug the front panel
PCB. Once the PCB is unplugged - remove the cover and set aside. Adjust the
print module stop block as needed to cause the pinion gears (B) to fully mesh
without binding. This is achieved by loosening the two screws (A) securing the
stop block to the frame and then moving the stop block right or left to cause it to
raise or lower. Retighten the screws once the proper height is reached.

5) Replace the cover and perform the auto cleaning until the print heads are filled

with ink and printing a full image.

6) As a final test of the print module installation, run a test pattern to check the print

quality. You should observe an even grid of rectangles.