beautypg.com

Installation – Lincoln Electric V155-S User Manual

Page 14

background image

INSTALLATION

A-6

A-6

INVERTEC® V155-S

Retur

n

to

Section

TOC

Retur

n

to

Section

TOC

Retur

n

to

Section

TOC

Retur

n

to

Section

TOC

Retur

n

to

Master

TOC

Retur

n

to

Master

TOC

Retur

n

to

Master

TOC

Retur

n

to

Master

TOC

REPLACEMENT QUICK DISCONNECT PLUG (FOR
STICK ELECTRODE CABLE)

The INVERTEC® V155-S comes with a factory assem-

bled stick electrode holder, cable and Twist-Mate™

adapter plug. If a replacement cable is ever needed a

K852-25 Twist-Mate™ plug will be needed.

To attach the K852-25 plug:

1. Cut off welding cable lug, if present.

2. Remove .75 in. (19mm) of welding cable insulation.

3. Slide rubber boot onto cable end. The boot end may

be trimmed to match the cable diameter. Use soap

or other nonpetroleum-based lubricant to help slide

the boot over the cable, if needed.

4. Cut 45-50% of the copper strands back 1/4” (6 mm).

5. Fold copper strands over cut strands and insert into

ferrule.

6. Slide the copper ferrule into the brass plug.

7. Tighten set screw to collapse copper tube. Screw

must apply pressure against welding cable. The top

of the set screw will be well below the surface of the

brass plug after tightening.

19 mm

.75 in.

WELDING CABLE

BOOT

TRIM, IF REQ'D

TO FIT OVER CABLE

6 mm

.25 in.

WELDING CABLE

12 mm max.

.50 in. max

WELDING CABLE

COPPER FERRULE

SET SCREW

BRASS PLUG

COPPER TUBE