Installation – Lincoln Electric V155-S User Manual
Page 10
INSTALLATION
A-2
A-2
INVERTEC® V155-S
Input Circuit
120 Vac
230 Vac
120 Vac
230 Vac
Maximum Open Circuit Voltage
75 Volts Max.
Duty Cycle
100%
30%
Output Current Range
5-155 Amps
INPUT - SINGLE PHASE ONLY
RATED OUTPUT
OUTPUT
Height
Width
Depth
Weight
11.3
6.2 in.
15.4in.
Approx. 14.7lbs.
288 mm
158 mm
392 mm
6.7 kgs.
PHYSICAL DIMENSIONS
TEMPERATURE RANGES
OPERATING TEMPERATURE RANGE
-10°C to +40°C
STORAGE TEMPERATURE RANGE
-25°C to +55°C
RECOMMENDED INPUT WIRE AND FUSE SIZES FOR MAXIMUM RATED OUTPUT
INPUT VOLTAGE /
FREQUENCY (HZ)
230/60
120/60
MAXIMUM TIME-DELAY CIRCUIT
BREAKER OR FUSE SIZE (AMPS)
30
TYPE S, SO ST, STO, OR EXTRA
HARD USAGE INPUT CORD AWG
3 Conductor, 12 AWG
Input Voltages / 50 /60 Hz.
120Vac ± 10%
230Vac ± 10%
Max. Input Current at rated Output
100% 30%
25A 34 A
23A 33 A
Input Power at Rated Output
100% 30%
2.2kw 3.0kw
3.0kw 5.0kw
Output Amps
75A (Stick)
105A (TIG)
100A (Stick)
100A (TIG)
100A (Stick)
130A (TIG)
145A (Stick)
155A (TIG)
Output Volts
23.0 Vdc
14.2 Vdc
24.0 Vdc
14.0 Vdc
24.0 Vdc
15.2 Vdc
25.8 Vdc
16.2 Vdc
Type of Output
DC