Lenovo THINKSERVER TS100 6434 User Manual
Page 75

Table
11.
Abbreviated
list
of
POST
error
codes
(continued)
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
the
parts
listing
in
the
Hardware
Maintenance
Manual
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
code
Description
Action
5962
DVD
drive
configuration
error.
1.
Run
the
Configuration/Setup
Utility
program
and
load
the
default
settings
(see
2.
Reseat
the
following
components:
a.
DVD
drive
cable
b.
DVD
drive
c.
System
board
3.
Replace
the
components
listed
in
step
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
00012000
Processor
machine
check
error.
1.
(Trained
service
technician
only)
Reseat
the
microprocessor.
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
(Trained
service
technician
only)
Microprocessor
b.
(Trained
service
technician
only)
System
board
00019701
Microprocessor
failed
the
built
in
self-test
(BIST).
1.
(Trained
service
technician
only)
Reseat
the
microprocessor.
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
(Trained
service
technician
only)
Microprocessor
b.
(Trained
service
technician
only)
System
board
01298001
No
update
data
for
microprocessor.
1.
Update
the
BIOS
code
again
(see
the
Hardware
Maintenance
Manual
).
2.
(Trained
service
technician
only)
Reseat
the
microprocessor.
3.
(Trained
service
technician
only)
Replace
the
microprocessor.
01298101
Bad
update
data
for
processor.
1.
Update
the
BIOS
code
again
(see
the
Hardware
Maintenance
Manual
).
2.
(Trained
service
technician
only)
Reseat
the
microprocessor.
3.
(Trained
service
technician
only)
Replace
the
microprocessor.
Chapter
5.
Solving
problems
61