Lenovo THINKSERVER TS100 6434 User Manual

Page 68

background image

Table

11.

Abbreviated

list

of

POST

error

codes

(continued)

v

Follow

the

suggested

actions

in

the

order

in

which

they

are

listed

in

the

Action

column

until

the

problem

is

solved.

v

See

the

parts

listing

in

the

Hardware

Maintenance

Manual

to

determine

which

components

are

customer

replaceable

units

(CRU)

and

which

components

are

field

replaceable

units

(FRU).

v

If

an

action

step

is

preceded

by

“(Trained

service

technician

only),”

that

step

must

be

performed

only

by

a

trained

service

technician.

Error

code

Description

Action

164

Memory

size

has

changed.

1.

Run

the

Configuration/Setup

Utility

program,

select

Load

Default

Settings

.

2.

Reseat

the

DIMM.

3.

Replace

the

following

components

one

at

a

time,

in

the

order

shown,

restarting

the

server

each

time:

a.

DIMM

b.

(Trained

service

technician

only)

System

board

175

Service

processor

flash

code

damaged

or

not

loaded.

Note:

In

this

case,

the

service

processor

is

the

optional

Remote

Supervisor

Adapter

II

SlimLine.

1.

Update

the

Remote

Supervisor

Adapter

II

SlimLine

firmware

(see

the

instructions

that

are

included

with

the

adapter).

2.

Replace

the

Remote

Supervisor

Adapter

II

SlimLine.

178

Security

hardware

error.

1.

Run

the

Configuration/Setup

Utility

program,

select

Load

Default

Settings

,

and

save

the

settings.

2.

(Trained

service

technician

only)

Replace

the

system

board.

184

Power-on

password

damaged.

1.

Run

the

Configuration/Setup

Utility

program,

select

Load

Default

Settings

,

and

save

the

settings.

2.

Reseat

the

battery.

3.

Clear

CMOS.

See

the

Hardware

Maintenance

Manual

for

information

about

how

to

clear

CMOS.

4.

Replace

the

following

components

one

at

a

time,

in

the

order

shown,

restarting

the

server

each

time:

a.

Battery

b.

(Trained

service

technician

only)

System

board

187

VPD

serial

number

not

set.

1.

Set

the

serial

number

by

updating

the

BIOS

code

level

(see

“Updating

the

firmware”

in

the

Hardware

Maintenance

Manual.

2.

(Trained

service

technician

only)

Replace

the

system

board.

54

ThinkServer

TS100

Types

6431,

6432,

6433,

6434:

Installation

Guide