Lenovo THINKSERVER TS100 6434 User Manual

Page 71

background image

Table

11.

Abbreviated

list

of

POST

error

codes

(continued)

v

Follow

the

suggested

actions

in

the

order

in

which

they

are

listed

in

the

Action

column

until

the

problem

is

solved.

v

See

the

parts

listing

in

the

Hardware

Maintenance

Manual

to

determine

which

components

are

customer

replaceable

units

(CRU)

and

which

components

are

field

replaceable

units

(FRU).

v

If

an

action

step

is

preceded

by

“(Trained

service

technician

only),”

that

step

must

be

performed

only

by

a

trained

service

technician.

Error

code

Description

Action

178x

Fixed

disk

error.

Note:

x

is

the

drive

that

has

the

error.

1.

Run

the

hard

disk

drive

diagnostic

tests

on

drive

x

(see

“Running

the

diagnostic

programs”

in

the

Hardware

Maintenance

Manual

).

2.

Reseat

the

following

components,

depending

on

the

server

model:

v

Hot-swap

models:

Hard

disk

drive

v

Simple-swap

models:

a.

Hard

disk

drive

x

b.

Hard

disk

drive

x

cable

3.

Replace

the

following

components

one

at

a

time,

depending

on

the

server

model,

in

the

order

shown,

restarting

the

server

each

time:

v

Hot-swap

models:

a.

Hard

disk

drive

x

b.

Hard

disk

drive

backplane

v

Simple-swap

models:

a.

Hard

disk

drive

x

b.

Hard

disk

drive

x

cable

4.

(Trained

service

technician

only)

Replace

the

system

board.

1800

Unavailable

PCI

hardware

interrupt.

1.

Run

the

Configuration/Setup

Utility

program

and

adjust

the

adapter

settings.

2.

Remove

each

adapter

one

at

a

time,

restarting

the

server

each

time,

until

the

failing

adapter

is

isolated.

Chapter

5.

Solving

problems

57